Includes decoupling mat for the selected area, two Pro Cable heating cables (13.78 W/m), a black XL 25A WiFi thermostat and floor sensor.
Cable spacing: 2 studs approximately 230 W/m², 3 studs approximately 150 W/m², 4 studs approximately 115 W/m². Set sizes are based on approximately 150 W/m². Changing spacing changes the heated area, not total output. Additional decoupling mat may be required.
Never cut, extend, cross or allow heating cables to touch. Connect both cables in parallel, never in series. Measure resistance before, during and after installation. Place the replaceable floor sensor in a protective conduit between cables. Have an electrician size the circuit, wiring and protection for the total output. A 25A thermostat does not increase the capacity of a 16A circuit.